I
was trying to cut a key and my ITL 950/950C just quit running.
A.
You might
need to replace one of two fuses:
Unplug the machine from its power source,
Remove the four 6/32 machine screws holding the power
supply on the rear of the machine and slide the power
supply unit out to view the top of the circuit board
Locate the fuses: The fuse
on the switch side is a 2-amp slow blow that protects
the line from internal shorts. The other is a 10-amp
slow blow that protects the cutter motor.
Note: replace the fuse
with a slow blow type.
Q.
The spacing
has suddenly changed on my ITL 950/950C.
A.
Restore the
calibration numbers:
Lightning strikes, power
outages, voltage spikes can lead to the loss of the callibration
numbers set at the factory. To check or update the calibration
numbers:
Switch off the machine and unplug from the power source.
Unscrew the 4 x Phillips screws at the bottom of the
control head to reveal your calibration numbers. (See
right). Write down their numbers. Reassemble.
Turn
on your machine. When in Ready
mode press the
keys –,
8,
mfg
to display current space setting.
Press mfg
again to show the current depth setting. If the results
read space ABS 1350 and depth 450, the computer has
returned to the factory default and the numbers for
the machine must be re-entered. Take the following steps:
Key in -,
8,
mfg
Enter your machine's
space number on the keypad, followed by the mfg
key
Pressmfg to view
the current depth number and press mfg
once more to install the new depth calibration,
Q.
Which keys does the ITL Sidewinder
Cut?
A.
The ITL Sidewinder can handle
multiple cuts includingVolkswagen
2-track, BMW 4-track and Mercedes
4-track. Here's the full list.